Parameter Descriptions
9-23 Parameters for Signals
Array [1000]
Read only
Option:
[1678] Analog Out X45/1 [mA]
[1679] Analog Out X45/3 [mA]
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
[1684] Comm. Option STW
[1685] FC Port CTW 1
[1686] FC Port REF 1
[1690] Alarm Word
[1691] Alarm Word 2
[1692] Warning Word
[1693] Warning Word 2
[1694] Ext. Status Word
[1860] Digital Input 2
[3310] Synchronization Factor Master
(M:S)
[3311] Synchronization Factor Slave
(M:S)
[3401] PCD 1 Write to MCO
[3402] PCD 2 Write to MCO
[3403] PCD 3 Write to MCO
[3404] PCD 4 Write to MCO
[3405] PCD 5 Write to MCO
[3406] PCD 6 Write to MCO
[3407] PCD 7 Write to MCO
[3408] PCD 8 Write to MCO
[3409] PCD 9 Write to MCO
[3410] PCD 10 Write to MCO
[3421] PCD 1 Read from MCO
[3422] PCD 2 Read from MCO
[3423] PCD 3 Read from MCO
[3424] PCD 4 Read from MCO
[3425] PCD 5 Read from MCO
[3426] PCD 6 Read from MCO
[3427] PCD 7 Read from MCO
[3428] PCD 8 Read from MCO
[3429] PCD 9 Read from MCO
[3430] PCD 10 Read from MCO
[3440] Digital Inputs
[3441] Digital Outputs
[3450] Actual Position
[3451] Commanded Position
[3452] Actual Master Position
[3453] Slave Index Position
[3454] Master Index Position
[3455] Curve Position
[3456] Track Error
[3457] Synchronizing Error
[3458] Actual Velocity
[3459] Actual Master Velocity
[3460] Synchronizing Status
FC 300 Programming Guide
9-23 Parameters for Signals
Array [1000]
Read only
Function:
Option:
[3461] Axis Status
[3462] Program Status
[3464] MCO 302 Status
[3465] MCO 302 Control
[3470] MCO Alarm Word 1
[3471] MCO Alarm Word 2
9-27 Parameter Edit
Option:
[0]
[1]
9-28 Process Control
Option:
[0]
[1]
9-44 Fault Message Counter
Range:
0
*
9-45 Fault Code
Range:
0
*
®
MG.33.M9.02 - VLT
is a registered Danfoss trademark
Function:
Parameters can be edited via Profibus, the standard
RS485 interface, or the LCP.
Disabled Disables editing via Profibus.
Enabled Enables editing via Profibus.
*
Function:
Process control (setting of Control Word, speed
reference, and process data) is possible via either
Profibus or standard fieldbus but not both
simultaneously. Local control is always possible
via the LCP. Control via process control is possible
via either terminals or fieldbus depending on the
settings in par. 8-50 Coasting Select to
par. 8-56 Preset Reference Select.
Disable
Disables process control via Profibus, and enables
process control via standard fieldbus or Profibus
Master class 2.
Enable
Enables process control via Profibus Master Class
*
cyclic
1, and disables process control via standard
master
fieldbus or Profibus Master class 2.
Function:
[0 - 65535 ] This parameter displays the number of error
events stored in par. 9-45 Fault Code and
par. 9-47 Fault Number. The maximum buffer
capacity is eight error events. The buffer and
counter are set to 0 upon reset or power-up.
Function:
[0 - 0 ] This buffer contains the alarm word for all alarms and
warnings that have occurred since last reset or
power-up. The maximum buffer capacity is eight
error events.