1.1.7 Pulse Start/Stop
Terminal 18 = par. 5-10 Terminal 18 Digital InputLatched start,
[9]
Terminal 27= par. 5-12 Terminal 27 Digital InputStop inverse,
[6]
Terminal 37 = Safe stop (where available!)
10
FC 300 Programming Guide
1.1.8 Speed Up/Down
Terminals 29/32 = Speed up/down:
NOTE: Terminal 29 only in FC x02 (x=series type).
®
MG.33.M9.02 - VLT
is a registered Danfoss trademark
Terminal 18 = par. 5-10 Terminal 18 Digital Input Start
[9] (default)
Terminal 27 = par. 5-12 Terminal 27 Digital Input
Freeze reference [19]
Terminal 29 = par. 5-13 Terminal 29 Digital Input
Speed up [21]
Terminal 32 = par. 5-14 Terminal 32 Digital Input
Speed down [22]