Parameter Lists
4.1.9 8-** Comm. and Options
Par.
Parameter description
No. #
8-0* General Settings
8-01
Control Site
8-02
Control Word Source
4
4
8-03
Control Word Timeout Time
8-04
Control Word Timeout Function
8-05
End-of-Timeout Function
8-06
Reset Control Word Timeout
8-07
Diagnosis Trigger
8-08
Readout Filtering
8-1* Ctrl. Word Settings
8-10
Control Word Profile
8-13
Configurable Status Word STW
8-14
Configurable Control Word CTW
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC Port Baud Rate
8-33
Parity / Stop Bits
8-34
Estimated cycle time
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Max Inter-Char Delay
8-4* FC MC protocol set
8-40
Telegram selection
8-41
Parameters for signals
8-42
PCD write configuration
8-43
PCD read configuration
8-5* Digital/Bus
8-50
Coasting Select
8-51
Quick Stop Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-57
Profidrive OFF2 Select
8-58
Profidrive OFF3 Select
8-8* FC Port Diagnostics
8-80
Bus Message Count
8-81
Bus Error Count
8-82
Slave Messages Rcvd
8-83
Slave Error Count
8-9* Bus Jog
8-90
Bus Jog 1 Speed
8-91
Bus Jog 2 Speed
172
FC 300 Programming Guide
Default value
[0] Digital and ctrl.word
null
1.0 s
null
[1] Resume set-up
[0] Do not reset
[0] Disable
null
[0] FC profile
null
[1] Profile default
[0] FC
1 N/A
null
[0] Even Parity, 1 Stop Bit
0 ms
10 ms
SR
SR
[1] Standard telegram 1
0
SR
SR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
0 N/A
0 N/A
0 N/A
0 N/A
100 RPM
200 RPM
®
MG.33.M9.02 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion
index
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-
Uint8
-3
Uint32
-3
Uint16
-3
Uint16
-5
Uint16
-
Uint8
-
Uint16
-
Uint16
-
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint32
0
Uint32
0
Uint32
0
Uint32
67
Uint16
67
Uint16