Danfoss FC 300 Programming Manual page 151

Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

Parameter Descriptions
3.17.6 16-8* Fieldbus & FC Port
Parameters for reporting the BUS references and control
words.
16-80 Fieldbus CTW 1
Range:
Function:
0 N/A
[0 - 65535
View the two-byte Control word (CTW)
*
N/A]
received from the Bus-Master. Interpretation
of the Control word depends on the fieldbus
option installed and the Control word profile
selected in par. 8-10 Control Profile.
For more information please refer to the
relevant fieldbus manual.
16-82 Fieldbus REF 1
Range:
Function:
0 N/A
[-200 - 200
View the two-byte word sent with the
*
N/A]
control word form the Bus-Master to set the
reference value.
For more information please refer to the
relevant fieldbus manual.
16-84 Comm. Option STW
Range:
Function:
0 N/A
[0 - 65535 N/A] View the extended fieldbus comm.
*
option status word.
For more information please refer to the
relevant fieldbus manual.
16-85 FC Port CTW 1
Range:
Function:
0 N/A
[0 - 65535
View the two-byte Control word (CTW)
*
N/A]
received from the Bus-Master. Interpretation
of the control word depends on the fieldbus
option installed and the Control word
profile selected in par. 8-10 Control Profile.
16-86 FC Port REF 1
Range:
Function:
0 N/A
[-200 - 200
View the two-byte Status word (STW) sent to
*
N/A]
the Bus-Master. Interpretation of the Status
word depends on the fieldbus option instal-
led and the Control word profile selected in
par. 8-10 Control Profile.
FC 300 Programming Guide
3.17.7 16-9* Diagnosis Read-Outs
16-90 Alarm Word
Range:
0 N/A
16-91 Alarm Word 2
Range:
0
*
16-92 Warning Word
Range:
0 N/A
16-93 Warning Word 2
Range:
0
*
16-94 Ext. Status Word
Range:
0
*
16-95 Ext. Status Word 2
Range:
0 N/A
16-96 Maintenance Word
Range:
0 N/A
®
MG.33.M9.02 - VLT
is a registered Danfoss trademark
Function:
[0 - 4294967295 N/A] View the alarm word sent via the
*
serial communication port in hex
code.
Function:
[0 - 4294967295 ] View the alarm word sent via the serial
communication port in hex code.
Function:
[0 - 4294967295 N/A] View the warning word sent via
*
the serial communication port in
hex code.
Function:
[0 - 4294967295 ] View the warning word sent via the serial
communication port in hex code.
Function:
[0 - 4294967295 ] Returns the extended warning word sent
via the serial communication port in hex
code.
Function:
[0 - 4294967295 N/A] Returns the extended warning
*
word 2 sent via the serial
communication port in hex code.
[0 - 4294967295 N/A]
*
3
3
Function:
151

Advertisement

Table of Contents
loading