Parameter Lists
4.1.18 18-** Data Readouts 2
Par.
Parameter description
No. #
18-3* Analog Readouts
18-36 Analog Input X48/2 [mA]
18-37 Temp. Input X48/4
4
4
18-38 Temp. Input X48/7
18-39 Temp. Input X48/10
18-6* Inputs & Outputs 2
18-60 Digital Input 2
18-90 PID Readouts
18-90 Process PID Error
18-91 Process PID Output
18-92 Process PID Clamped Output
18-93 Process PID Gain Scaled Output
4.1.19 30-** Special Features
Par.
Parameter description
No. #
30-0* Wobbler
30-00 Wobble Mode
30-01 Wobble Delta Frequency [Hz]
30-02 Wobble Delta Frequency [%]
30-03 Wobble Delta Freq. Scaling Resource
30-04 Wobble Jump Frequency [Hz]
30-05 Wobble Jump Frequency [%]
30-06 Wobble Jump Time
30-07 Wobble Sequence Time
30-08 Wobble Up/ Down Time
30-09 Wobble Random Function
30-10 Wobble Ratio
30-11 Wobble Random Ratio Max.
30-12 Wobble Random Ratio Min.
30-19 Wobble Delta Freq. Scaled
30-2* Adv. Start Adjust
30-20 High Starting Torque Time [s]
30-21 High Starting Torque Current [%]
30-22 Locked Rotor Protection
30-23 Locked Rotor Detection Time [s]
30-8* Compatibility (I)
30-80 d-axis Inductance (Ld)
30-81 Brake Resistor (ohm)
30-83 Speed PID Proportional Gain
30-84 Process PID Proportional Gain
184
FC 300 Programming Guide
Default value
0.000 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0.0 %
0.0 %
0.0 %
0.0 %
Default value
[0] Abs. Freq., Abs. Time
5.0 Hz
25 %
[0] No function
0.0 Hz
0 %
SR
10.0 s
5.0 s
[0] Off
1.0 N/A
10.0 N/A
0.1 N/A
0.0 Hz
0.00 s
100.0 %
[0] Off
0.10 s
SR
SR
SR
0.100 N/A
®
MG.33.M9.02 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
4-set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
FALSE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion
index
-3
Int32
0
Int16
0
Int16
0
Int16
0
Uint16
-1
Int16
-1
Int16
-1
Int16
-1
Int16
Conver-
Type
sion
index
-
Uint8
-1
Uint8
0
Uint8
-
Uint8
-1
Uint8
0
Uint8
-3
Uint16
-1
Uint16
-1
Uint16
-
Uint8
-1
Uint8
-1
Uint8
-1
Uint8
-1
Uint16
-2
Uint8
-1
Uint32
-
Uint8
-2
Uint8
-6
Int32
-2
Uint32
-4
Uint32
-3
Uint16

Advertisement

Table of Contents
loading

Table of Contents