Parameter Descriptions
13-52 SL Controller Action
Array [20]
Option:
Function:
[27] Coast
Coast [27] - the frequency converter coasts
immediately. All stop commands including
the coast command stop the SLC.
[28] Freeze output
Freeze output [28] - freezes the output
frequency of the frequency converter.
[29] Start timer 0
Start timer 0 [29] - starts timer 0, see par.
13-20 for further description.
[30] Start timer 1
Start timer 1 [30] - starts timer 1, see par.
13-20 for further description.
[31] Start timer 2
Start timer 2 [31] - starts timer 2, see par.
13-20 for further description.
[32] Set digital out
Set digital output A low [32] - any output with
A low
SL output A will be low.
[33] Set digital out
Set digital output B low [33] - any output with
B low
SL output B will be low.
[34] Set digital out
Set digital output C low [34] - any output with
C low
SL output Cwill be low.
[35] Set digital out
Set digital output D low [35] - any output
D low
with SL output D will be low.
[36] Set digital out
Set digital output E low [36] - any output with
E low
SL output E will be low.
[37] Set digital out
Set digital output F low [37] - any output with
F low
SL output F will be low.
[38] Set digital out
Set digital output A high [38] - any output
A high
with SL output A will be high.
[39] Set digital out
Set digital output B high [39] - any output
B high
with SL output B will be high.
[40] Set digital out
Set digital output C high [40] - any output
C high
with SL output C will be high.
[41] Set digital out
Set digital output D high [41] - any output
D high
with SL output D will be high.
[42] Set digital out
Set digital output E high [42] - any output
E high
with SL output E will be high.
[43] Set digital out
Set digital output F high [43] - any output
F high
with SL output Fwill be high.
[60] Reset Counter
Reset Counter A [60] - resets Counter A to
A
zero.
[61] Reset Counter
Reset Counter B [61] - resets Counter B to
B
zero.
[70] Start timer 3
Start Timer 3 [70] - Start Timer 3, see par.
13-20 for further description.
[71] Start timer 4
Start Timer 4 [71] - Start Timer 4, see par.
13-20 for further description.
[72] Start timer 5
Start Timer 5 [72] - Start Timer 5, see par.
13-20 for further description.
FC 300 Programming Guide
13-52 SL Controller Action
Array [20]
Option:
[73] Start timer 6
[74] Start timer 7
®
MG.33.M9.02 - VLT
is a registered Danfoss trademark
Function:
Start Timer 6 [73] - Start Timer 6, see par.
13-20 for further description.
Start Timer 7 [74] - Start Timer 7, see par.
13-20 for further description.