Parameters
Default
DI logic I/Q pin
0
DI logic C/Q pin
0
DI filter time I/Q pin
0
DI filter time C/Q pin 0
Table 35: "DI" (Digital Input) Parameters
Value Range
Description
0: DI not inverted
Operating mode as
(NO normally open)
digital input: The sig-
nal on pin 2 is not in-
verted
1: DI inverted (NC
Operating mode of
normally closed)
the digital input: The
signal on pin 2 is in-
verted
0: DI not inverted
Operating mode of
(NO normally open)
the digital input: The
signal on pin 4 is not
inverted
1: DI inverted (NC
Operating mode of
normally closed)
the digital input: The
signal on pin 4 is in-
verted
0: no filter
No filter active for de-
tecting a signal
change of the pin 2
input signal.
30: 3 ms filter time
Filter time setting for
detecting a signal
150: 15 ms filter time
change of the input
200: 20 ms filter time
signal; the filter time
is the amount of time
the signal must be
present in order for a
signal change to be
detected.
0: no filter
No filter active for de-
tecting a signal
change of the pin 4
input signal.
30: 3 ms filter time
Filter time setting for
detecting a signal
150: 15 ms filter time
change of the input
200: 20 ms filter time
signal; the filter time
is the amount of time
the signal must be
present in order for a
signal change to be
detected.