Settings Options; Profinet Parameters; Table 28 "Do" (Digital Output) Parameters - WAGO 765-1103/100-000 Manual

16-channel digital output; profinet; 24 v dc; 2.0 a; 8 × m12 connection
Table of Contents

Advertisement

Planning

6.3 Settings Options

6.3.1 PROFINET Parameters

"DO" (Digital Output) Parameters
The following table describes the parameters of the "Digital Output" submodule.
Parameter
Group
Digital PD
layout con-
figuration
Digital out-
put substi-
tute configu-
ration
Force mode
setting
Bluetooth
interface
configura-
tion
40
Product manual | Version: 2.2.0
16DO FLD PN DC 24V 2.0A
Parameter
Default
Value
Value
Range
PD layout
0
0: port-
based
1: pin-based Order of the process data of the digital inputs and digital
Digital out-
0
0: set digital
put substi-
output pins
tute configu-
to low
ration
1: set digital
output pins
to defined
substitute
value
2: hold last
value of dig-
ital output
pins
Digital out-
0
0 ... 65535
put substi-
tute value
Force mode
0
0: enable
setting
force mode
1: disable
force mode
Bluetooth
0
0: activation
configura-
of BT inter-
tion
face is al-
lowed
1: disable
activation of
BT inter-
face. BT in-
terface can-
not be acti-
vated via
optical sig-
nal
Table 28: "DO" (Digital Output) Parameters
Description
Order of the process data of the digital inputs and digital
outputs: port 1 (bit 0 and 1), port 2 (bit 2 and 3), ..., port 8
(bit 14 and 15) (default). For each port, first pin 4, then
pin 2 is transmitted.
outputs: pin 4 (port 1 ... 8), pin 2 (port 1 ... 8).
Set all digital outputs to low level in the event of error
(default).
Set digital outputs to a pre-defined substitute value in the
event of error. If this setting is used, the value of the
"Digital Output Substitute Value" parameter sets the sub-
stitute value.
Hold digital outputs at their last value in the event of an
error.
Substitute value as a bitmask for the digital outputs if the
"Set to Defined Value" setting is used; The input depends
on the "PD Layout" parameter. To assign bits 0 to 15 to
port and pin, see description of the "PD Layout" parame-
ter.
Use a binary-to-decimal converter to calculate this value.
The "Forcing" operating mode may be used (default).
The "Forcing" operating mode must not be used.
®
The Bluetooth
interface can be enabled by an optical
signal of a mobile device and in connection with the
WAGO I/O Field app.
®
The Bluetooth
interface cannot be enabled by an optical
signal of a mobile device and in connection with the
WAGO I/O Field app.