12-Volt Power Outlet - BRP BOMBARDIER DS250 2006 Shop Manual

Table of Contents

Advertisement

Section 05 ELECTRICAL SYSTEM
Subsection 04 (LIGHTS AND ACCESSORIES)
vmr2006-081-022_b
HORN SWITCH MAIN HARNESS CONNECTOR
WIRE
WHITE/BLACK and
battery ground
If voltage is not appropriate, check supply wire
from battery.
If voltage is good, check voltage at horn terminals
as follows.
Reconnect horn switch connector.
To get access to horn and terminals, remove front
fender. Refer to BODY.
Measure voltage as follows.
vmr2006-081-023_a
166
VOLTAGE
Battery voltage
HORN TERMINALS
HORN
SWITCH
WIRE
POSITION
Pressed
LIGHT GREEN and
and held
GREEN wires
If voltage is adequate, replace horn.
Otherwise, recheck voltage as follows.
vmr2006-081-023_b
HORN TERMINALS
HORN
SWITCH
WIRE
POSITION
Pressed
LIGHT GREEN and
and held
battery ground
If there is now voltage, check ground wire.
If there is still no voltage, check wire between
horn switch and horn.

12-VOLT POWER OUTLET

Test
Turn ignition switch on.
Unplug the power outlet connectors.
Use a multimeter and set it to Vdc.
Measure voltage as follows.
VOLTAGE
Battery
voltage
VOLTAGE
Battery
voltage
vmr2006-081