BRP BOMBARDIER DS250 2006 Shop Manual page 182

Table of Contents

Advertisement

vmr2006-081-002
Heat coolant to 123 °C (253 °F) and measure re-
sistance of sensor. It should be within 15 - 19 .
Otherwise, replace sensor.
Reinstall and reconnect sensor.
Refill cooling system. Refer to COOLING SYS-
TEM.
Remove front cover to gain access to module. Re-
fer to BODY.
Disconnect connector at engine overheat lamp
module.
vmr2006-081-020_a
Apply directly 12 Vdc on GREEN/BLACK wire and
connect battery ground to the other wire.
Measure voltage at lamp socket. Battery voltage
should be read.
vmr2006-081
Section 05 ELECTRICAL SYSTEM
Subsection 04 (LIGHTS AND ACCESSORIES)
vmr2006-081-020_c
If there is no voltage, check supply wire going to
lamp socket. If good, check ground wire of lamp
socket. If good, continue testing.
Measure voltage between WHITE/BLACK and
GREEN wires going to module. You should read
battery voltage.
vmr2006-081-020_d
If so, try a new module.
Otherwise, measure voltage between WHITE/
BLACK supply wire and battery ground. You
should read battery voltage.
163