BRP BOMBARDIER DS250 2006 Shop Manual page 41

Table of Contents

Advertisement

Section 02 TROUBLESHOOTING
Subsection 01 (TROUBLESHOOTING CHART)
STARTER DOES NOT TURN.
Symptom:
3. Poor contact of battery terminal(s) or ground cable connections.
-
Clean and tighten terminal(s).
4. Weak battery.
-
Recharge battery.
5. Poor contact or open circuit of: start button, engine stop switch, ignition switch or starting
solenoid.
-
Check and replace defective part.
6. Brake or Neutral switch is defective.
-
Check brake and/or neutral switch and wiring condition.
7. Faulty shift gear control module.
-
Check module/wiring and replace defective part.
8. Engine mechanical problem (ensure that other electric components are good).
-
Check engine.
STARTER TURNS, BUT DOES NOT CRANK THE ENGINE.
Symptom:
1. Weak battery.
-
Recharge or replace battery.
2. Poor contact of battery terminal(s).
-
Clean and tighten terminal(s).
3. Poor battery ground cable connection.
-
Clean and tighten.
4. Burnt or poor contact of solenoid switch contact disc.
-
Replace starting solenoid.
5. Broken or worn starter reduction gear.
-
Check and replace gear if defective.
6. Worn or damaged starting clutch.
-
Check and replace clutch if defective.
7. Defective electric starter.
-
Check and replace electric starter if defective.
STARTER MOTOR KEEPS TURNING.
Symptom:
1. Shorted starting solenoid switch winding.
-
Replace starter solenoid.
2. Melted solenoid contacts.
-
Replace starter solenoid.
3. Start button stuck.
-
Fix or remove mud/ice/dirt or replace it.
22
(cont'd)
vmr2006-065

Advertisement

Table of Contents