BRP BOMBARDIER DS250 2006 Shop Manual page 177

Table of Contents

Advertisement

Section 05 ELECTRICAL SYSTEM
Subsection 04 (LIGHTS AND ACCESSORIES)
HAZARD CONTROL
TURN
MODULE INPUTS
SIGNAL
SWITCH
WIRE COLOR
Left turn
PINK
Right turn
BROWN/WHITE
If there is no voltage, recheck as follows.
vmr2006-081-014_b
HAZARD CONTROL
TURN
MODULE INPUTS
SIGNAL
SWITCH
WIRE COLOR
Left turn
PINK
Right turn
BROWN/WHITE
If there is now voltage, check ground wire.
If there is no voltage, check wire from turn signal
switch.
Reconnect connector.
Output Signals from Hazard Control Module
IMPORTANT: Ensure hazard switch is OFF.
Turn ignition switch on.
Activate turn signal switch and read voltage as fol-
lows.
Disconnect 2-pin connector.
Use a multimeter and set it to Vdc.
Turn ignition switch on.
Activate turn signal switch and read voltage as fol-
lows.
158
VOLTAGE
Pulsating
battery
GREEN
voltage
VOLTAGE
Pulsating
Battery
battery
ground
voltage
vmr2006-081-015_a
HAZARD CONTROL
TURN
MODULE OUTPUTS
SIGNAL
SWITCH
WIRE COLOR
Left turn
ORANGE
LIGHT
Right turn
BLUE
If there is no voltage, replace hazard control mod-
ule.
If there is voltage, check wires from module to
turn signal lights.
Reconnect connector.
NOTE: To test the hazard lights system, set switch
to on and check output signals from module. Pul-
sating voltage must be present on both sides si-
multaneously. Otherwise, replace module.
Flasher Module
vmr2006-081-017_a
Check signals coming from hazard control module
as follows.
VOLTAGE
Battery
Pulsating
ground
battery voltage
vmr2006-081