Carburetor Side
Loosen the choke cable retaining plate then re-
move choke cable from its lever.
vmr2006-077-005_a
1. Choke cable retaining plate
2. Choke lever on carburetor
Multifunction Switch Side
Push the choke lever to FULL position.
Underneath multifunction switch, pull cable to
remove the cable housing from multifunction
switch.
vmr2006-077-016_a
1. Choke cable
2. Choke lever
3. Multifunction switch
Align the choke cable end with the lever slot then
remove the cable.
vmr2006-077-017
vmr2006-077
Section 04 FUEL SYSTEM
Subsection 01 (CARBURETOR AND FUEL TANK)
Lubrication
The choke cable must be lubricated with cable lu-
bricant (P/N 293 600 041) or an equivalent.
Always use a silicone-based lubricant. Us-
ing another lubricant (like a water-based lu-
bricant) could cause the throttle lever/cable
sticking or stiffness.
To lubricate the choke cable, remove cable from
multifunction switch and from carburetor.
Install the cable luber (P/N 529 035 738) on cable.
Insert the needle of lubricant can on cable luber
hole.
Always wear eye protection and gloves when
lubricating cables.
NOTE: Place a rag around cable luber to prevent
lubricant splash.
Put lubricant until it passes through the cable.
Place the cable in a vertical position during approx-
imately 15 minutes or until no lubricant flows out
of cable.
Reinstall cable.
Installation
Install the choke cable by reversing the removal
procedure.
WARNING
WARNING
121