STARTING SYSTEM LAYOUT

【A】Power lock
【C】Flameout switch
【E】Oil pump
【G】Start relay
【K】32Ah battery
Description of engine starting process:
1. Turn on the power lock 【A】, power on the whole vehicle, and check whether the upper gear of the
instrument 【B】 is in the N gear;
2. Turn on the fl ameout switch 【C】. After ECU 【D】 judges that it is powered on, it outputs a signal
to the oil pump relay, and the oil pump relay coil is closed;
3. After the oil pump relay works, the current is output to the oil pump 【E】, the oil pump starts to work,
and the oil pipe is fi lled with gasoline;4. Press and hold the start button 【F】 for a period of time, the
auxiliary start relay will close;
5. After the auxiliary starting relay works, output the starting signal to the starting relay 【G】;
6. After the starter relay works, the starter motor starts to work;
7. After the starter motor works, drive the engine to work through the gear, and the engine starts to start
at this time;
K
G
D
【B】Instrument 
【D】ECU
【F】Start button
【H】Fuse box
14 - 27
ELECTRICAL SYSTEM
B
F
H
A
C
E