ELECTRICAL SYSTEM

Performance parameters

Item
Calibration voltage
Operating voltage
Resistance
(20--25℃
Primary current
(Charging time 3.9ms)
Secondary voltage
(Load 35pF)
Ignition energy
(Zener voltage 1000V)

Fault diagnosis

The ECU does not perform the fault diagnosis function for
the ignition coil, so there is no ignition coil related code
in the fault code list. If there is no ignition, please check
whether the ignition coil connector is well connected,
A
whether the pins are deformed, and whether the ignition
coil wire and the spark plug are in good contact.
!
If the spark plug wire (point【A】in the left picture)
is installed incorrectly, it will cause the engine to shut
down.
14 - 56
Value
Min
Rated Max
/
14
6
14
P r i m a r y
466
530
winding
Secondary
8.27
9.4
winding
7.4
8.0
34
/
40
/
Unit
/
V
16.5
V
593
10.53
8.6
A
/
kV
/
mJ