5.4

(E) Environment setting parameters

To set the time
To set a limit for the reset function.
To shut off output if the operation panel
disconnects.
To force deceleration to a stop on the operation
panel.
To select the display language of the parameter
unit
To control the buzzer of the parameter unit and
operation panel
To adjust the LCD contrast of the parameter unit PU contrast adjustment
To turn OFF the operation panel when not using
it for a certain period of time
To switch the monitor display of the operation
panel to the PID set point setting screen by
simply turning the setting dial
To use the USB memory
To use the setting dial of the operation panel like
a potentiometer to set the frequency.
To disable the operation panel.
To change the frequency change increments
which changes when using the setting dial of the
operation panel
To use the regeneration unit to increase the
motor braking torque
To change the overload current rating
specification
To input a voltage between 480 V and 500 V
To prevent parameter rewriting
To restrict parameters with a password
To use parameters freely
To change parameter settings for an IPM motor
as a batch
To set multiple parameters by batch
To display the required parameters
To release the parameter copy warning (CP)
To reduce the motor noise and EMI
To understand the maintenance time of inverter
parts and peripheral devices
194
5. PARAMETERS
5.4 (E) Environment setting parameters
Downloaded from
ManualsNet.com
Purpose
search engine
Parameter to set
Real time clock function
P.E020 to P.E022
Reset selection/
disconnected PU
P.E100 to P.E102,
detection/PU stop
P.E107
selection/reset limit
PU display language
P.E103
selection
PU buzzer control
P.E104
P.E105
Display-off setting
P.E106
Direct setting
P.E108
USB host reset
P.E110
Operation panel operation
P.E200
selection
Frequency change
P.E201
increment amount setting
Regenerative brake
P.E300
selection
Multiple rating setting
P.E301
Input voltage mode
P.E302
selection
Parameter write disable
P.E400
selection
Password
P.E410, P.E411
Free parameter
P.E420, P.E421
PM parameter initialization
P.E430
Automatic parameter
P.E431
setting
Applicable parameter
display and user group
P.E440 to P.E443
function
Parameter copy alarm
P.E490
release
PWM carrier frequency
P.E600 to P.E602
changing
Inverter parts life display
P.E700 to P.E707
Maintenance output
P.E710 to P.E715
function
Current average value
P.E720 to P.E722
monitor signal
Refer to
page
Pr.1006 to
195
Pr.1008
Pr.75
196
Pr.145
200
Pr.990
200
Pr.991
200
Pr.1048
200
Pr.1000
201
Pr.1049
201
Pr.161
202
Pr.295
203
Pr.30
566
Pr.570
204
Pr.977
205
Pr.77
206
Pr.296, Pr.297
208
Pr.888, Pr.889
210
Pr.998
183
Pr.999
211
Pr.160, Pr.172 to
215
Pr.174
Pr.989
579
Pr.72, Pr.240,
218
Pr.260
Pr.255 to Pr.259,
220
Pr.506 to Pr.508
Pr.503 to Pr.504,
224
Pr.686 to Pr.689
Pr.555 to Pr.557
225