• Set desired values as the motor constant parameters.
Iq = torque current, I
2
Iq =
I
100
First motor
Second
Pr.
motor Pr.
82
455
90
458
91
459
92
460
93
461
94
462
859
860
298
560
*1
For the FR-F820-02330(55K) or lower, and FR-F840-01160(55K) or lower.
*2
For the FR-F820-03160(75K) or higher, and FR-F840-01800(75K) or higher.
NOTE
• If "wye connection" or "delta connection" is incorrectly selected in Pr.71, Advanced magnetic flux vector control is not
performed properly.
• If "9999" is set, tuning data will be invalid and the constant values for Mitsubishi Electric motors (SF-PR, SF-JR, SF-HR, SF-
JRCA, SF-HRCA and so on) are used.
 Tuning the second motor
• When one inverter switches the operation between two different motors, set the second motor in Pr.450 Second applied
motor. (Refer to
• Turning ON the RT signal enables the parameter settings for the second motor as follows.
Motor capacity
Number of motor poles
Motor excitation current
Rated motor voltage
Rated motor frequency
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)/d-axis inductance (Ld)
Motor constant (L2)/q-axis inductance (Lq)
Motor constant (X)
Auto tuning setting/status
Frequency search gain
NOTE
• The RT signal is assigned to terminal RT in the initial status. Set "3" in one of Pr.178 to Pr.189 (Input terminal function
selection) to assign the RT signal to another terminal.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) may affect the other functions.
Set parameters after confirming the function of each terminal.
Downloaded from
ManualsNet.com
rated current, I
no load current
100 =
0 =
2
- I
0
Name
Motor excitation current (no
load current)
Motor constant (r1)
Motor constant (r2)
Motor constant (x1)
Motor constant (x2)
Motor constant (xm)
Torque current/Rated PM motor
current
Frequency search gain
page
379.) In the initial setting, no second motor is applied.
Function
search engine
Setting range
*1
0 to 500 A, 9999
*2
0 to 3600 A, 9999
*1
0 to 50 Ω, 9999
*2
0 to 400 mΩ, 9999
*1
0 to 50 Ω, 9999
*2
0 to 400 mΩ, 9999
*1
0 to 50 Ω, 9999
*2
0 to 3600 mΩ, 9999
*1
0 to 50 Ω, 9999
*2
0 to 3600 mΩ, 9999
*1
0 to 500 Ω, 9999
*2
0 to 100 Ω, 9999
*1
0 to 500 A, 9999
*2
0 to 3600 A, 9999
0 to 32767, 9999
RT signal-ON
(second motor)
Pr.453
Pr.454
Pr.455
Pr.456
Pr.457
Pr.458
Pr.459
Pr.460
Pr.461
Pr.462
Pr.463
Pr.560
Setting increments
Initial value
*1
0.01 A
*2
0.1 A
*1
0.001 Ω
*2
0.01 mΩ
*1
0.001 Ω
*2
0.01 mΩ
*1
0.001 Ω
9999
*2
0.1 mΩ
*1
0.001 Ω
*2
0.1 mΩ
0.01 Ω
*1
0.01 A
*2
0.1 A
1
RT signal-OFF
(first motor)
Pr.80
Pr.81
Pr.82
Pr.83
Pr.84
Pr.90
Pr.91
Pr.92
Pr.93
Pr.94
Pr.96
Pr.298
5. PARAMETERS
5.10 (C) Motor constant parameters
1
2
3
4
5
6
7
8
9
10
391