Mitsubishi Electric FR-F800 Series Instruction Manual page 316

Hide thumbs Also See for FR-F800 Series:

Advertisement

Monitor item
Output frequency
*2
Output current
Output voltage
Frequency setting value
Motor speed
Motor torque
Converter output
*2
voltage
Electronic thermal O/L
relayLoad factor
Output current peak
value
Converter output voltage
peak value
Input power
*2
Output power
Load meter
Motor excitation current
Reference voltage output —
Motor load factor
Motor output
Power saving effect
PID set point
PID measured value
PID deviation
Motor thermal load factor 0.1%
Inverter thermal load
factor
PID measured value 2
PID input pressure value 0.1%
PLC function analog
output
BACnet terminal FM/CA
output level
BACnet terminal AM
output level
Downloaded from
ManualsNet.com
Increment
Pr.54 (FM/CA)
and unit
Pr.158 (AM) setting
0.01 Hz
1
*1
2
0.01/0.1 A
0.1 V
3
0.01 Hz
5
1 (r/min)
6
0.1%
7
0.1 V
8
9
0.1%
10
*1
11
0.01/0.1 A
0.1 V
12
*1
13
0.01/0.1 kW
*1
14
0.01/0.1 kW
0.1%
17
*1
18
0.01 A/0.1 A
21
0.1%
24
*1
34
0.01/0.1 kW
Increment and
unit vary
depending on
50
the parameter
settings.
0.1%
52
0.1%
53
*4
0.1%
54
61
0.1%
62
0.1%
67
69
0.1%
70
*5
0.1%
85
*4
0.1%
86
search engine
Terminal FM/CA/AM
Negative
full-scale value
output
*3
Pr.55
Pr.56
200 V class: 400 V
400 V class: 800 V
Pr.55
The value converted
*3
with the Pr.37, Pr.144
value from Pr.55.
Pr.866
200 V class: 400 V
400 V class: 800 V
Electronic thermal O/L
relay (100%)
Pr.56
200 V class: 400 V
400 V class: 800 V
Inverter rated power ×
2
Inverter rated power ×
2
Pr.866
Pr.56
200%
Rated motor capacity
Inverter capacity
100%
100%
100%
Motor thermal
activation level
(100%)
Inverter thermal
activation level
(100%)
100%
100%
100%
100%
100%
5.8 (M) Item and output signal for monitoring
Remarks
Refer to
page 303
for the monitoring of
the operation speed.
For manufacturer setting. Do not set.
Terminal FM:
When Pr.291 = "0 or 1", output is 1440
pulses/s.
When Pr.291 ≠ "0 or 1", output is 50k
pulses/s.
Terminal CA: Output is 20 mA.
Terminal AM: Output is 10 V.
For the information of the power saving
effect monitoring, refer to
page
324.
Refer to
page 432
for the PID control.
Refer to
page 432
for the PID control.
Displays the input pressure value of
the PID input pressure control function.
Valid by setting Pr.414 = "1 or 2".
Refer to
page 483
for the PLC function.
The value set in the Analog Output
object (ID=0: Terminal FM/CA) for
BACnet communication is output.
The value set in the Analog Output
object (ID=1: Terminal AM) for BACnet
communication is output. (The output
is always negative regardless of the
Pr.290 setting when the monitored
value is negative.)
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
315