Download Print this page

Mitsubishi Electric FR-F800 Series Instruction Manual page 516

Hide thumbs Also See for FR-F800 Series:

Advertisement

General flowchart
CAUTION
• Always set the communication check time interval before starting operation to prevent hazardous conditions.
• Data communication is not started automatically but is made only once when the computer provides a communication
request. If communication is disabled during operation due to signal cable breakage etc., the inverter cannot be stopped.
When the communication check time interval has elapsed, the inverter output will be shut off (E.PUE, E.SER).
Turn the RES signal of the inverter ON or shut off the power supply to coast the motor to a stop.
• If communication is broken due to signal cable breakage, computer fault etc., the inverter does not detect such a fault.
This should be fully noted.
 Setting items and set data
• After completion of parameter settings, set the instruction codes and data, then start communication from the computer to
allow various types of operation control and monitoring.
Item
Operation mode
Downloaded from
ManualsNet.com
Read/
Instruction
write
code
H0000: Network operation
Read
H7B
H0001: External operation, External operation (JOG operation)
H0002: PU operation, External/PU combined operation, PUJOG operation
H0000: Network operation (Setting is available via communication through
the RS-485 terminals.)
Write
HFB
H0001: External operation
H0002: PU operation (Setting is available via communication through the PU
connector.)
search engine
Port open
Communication setting
Time out setting
Send data processing
○Data setting
○Sum code calculation
○Data transmission
Receive data waiting
Receive data processing
○Receive data processing
○Screen display
Data description
5.12 (N) Communication operation parameters
1
2
3
4
5
6
7
8
9
Number of
data digits
*1
(format)
4 digits (B and
10
E/D)
4 digits (A and
C/D)
515
5. PARAMETERS

Advertisement

loading