Symbol
(a)
Inverter (FR-F800)
(b)
Three-phase AC power supply
Molded case circuit breaker (MCCB), earth
(c)
leakage circuit breaker (ELB), or fuse
(d)
Magnetic contactor (MC)
(e)
AC reactor (FR-HAL)
(f)
DC reactor (FR-HEL)
(g)
Noise filter (FR-BLF)
(h)
High power factor converter (FR-HC2)
Multifunction regeneration converter (FR-
(i)
*1
XC)
(j)
Power regeneration common converter
*1
(FR-CV)
(k)
Power regeneration converter (MT-RC)
(l)
Brake unit (FR-BU2, FR-BU, BU)
(m)
Resistor unit (FR-BR, MT-BR5)
(n)
USB connection
(o)
Noise filter (FR-BSF01/FR-BLF)
(p)
Induction motor
Contactor
(q)
Example) No-fuse switch (DSN type)
(r)
IPM motor (MM-EFS/MM-THE4)
*1
To select a stand-alone option, refer to the Instruction Manual of each option.
26
2. INSTALLATION AND WIRING
2.1 Peripheral devices
Downloaded from
ManualsNet.com
Name
The life of the inverter is influenced by the surrounding air temperature.
The surrounding air temperature should be as low as possible within the
permissible range. This must be noted especially when the inverter is
installed in an enclosure.
Incorrect wiring may lead to damage of the inverter. The control signal lines
must be kept fully away from the main circuit lines to protect them from
noise.
The built-in EMC filter can reduce the noise.
Must be within the permissible power supply specifications of the inverter.
Must be selected carefully since an inrush current flows in the inverter at
power ON.
Install this to ensure safety.
Do not use this to start and stop the inverter. Doing so will shorten the life
of the inverter.
Install this to suppress harmonics and to improve the power factor.
An AC reactor (FR-HAL) (option) is required when installing the inverter
near a large power supply system (1000 kVA or more). Under such
condition, the inverter may be damaged if you do not use a reactor.
Select a reactor according to the applied motor capacity.
Install this to suppress harmonics and to improve the power factor.
Select a reactor according to the applied motor capacity.
For the FR-F820-03160(75K) or higher and the FR-F840-01800(75K) or
higher, always connect the FR-HEL.
When using the DC reactor with the FR-F820-02330(55K) or lower, or the
FR-F840-01160(55K) or lower, remove the jumper across terminals P/+ and
P1 before connecting the DC reactor to the inverter.
The FR-F820-02330(55K) or lower and the FR-F840-01160(55K) or lower
are equipped with the common mode choke.
Suppresses the power supply harmonics significantly. Install this as
required.
Provides a large braking capability. Install this as required.
*1
*1
Allows the inverter to provide the optimal regenerative braking capability.
Install this as required.
*1
Connect between the inverter and a personal computer with a USB (ver.
1.1) cable.
Use a USB memory device to copy parameter settings or use the trace
function.
Install this to reduce the electromagnetic noise generated from the inverter.
The noise filter is effective in the range from about 0.5 to 5 MHz.
A wire should be wound four turns at maximum.
Connect a squirrel-cage induction motor.
Connect this for an application where a PM motor is driven by the load even
while the inverter power is OFF. Do not open or close the contactor while
the inverter is running (outputting).
Use the specified motor. An IPM motor cannot be driven by the commercial
power supply.
search engine
Overview
Refer to
page
36, 45,
95
638
28
102
101
101
93
83
84
86
87
80
78
93
641