NOTE
• The adjustable 5 points V/F is enabled under V/F control.
• When Pr.19 Base frequency voltage = "8888 or 9999", setting of Pr.71 = "2" is not available. To set "2" in Pr.71, set the rated
motor voltage in Pr.19.
• A write disable error "
• Set frequency or voltage for each point in Pr.100 to Pr.109 within the range of Pr.3 Base frequency or Pr.19 Base frequency
voltage.
• When Pr.71 = "2", Pr.47 Second V/F (base frequency) is not available.
• When Pr.71 = "2", the inverter calculates the characteristic of the electronic thermal relay for a standard motor.
• By simultaneously using Pr.60 Energy saving control selection and the adjustable 5 points V/F, further energy saving effect
is expected.
• The Pr.0 Torque boost and Pr.12 DC injection brake operation voltage settings are automatically changed according to
the Pr.71 setting. (Refer to
Parameters referred to
Pr.0 Torque
boostpage 551
Pr.3 Base frequency, Pr.19 Base frequency
Pr.12 DC injection brake operation
Pr.47 Second V/F (base
Pr.60 Energy saving control
Pr.71 Applied motor, Pr.450 Second applied
5.13.7 SF-PR slip amount adjustment mode
V/F
V/F
V/F
• As compared to our conventional SF-JR motor, the slip amount is small for the high-performance energy-saving SF-PR
motor. When replacing the SF-JR to the SF-PR, the slip amount is reduced and the rotations per minute increases.
Therefore, when the SF-PR is used with the same frequency setting as that of the SF-JR, power consumption may
increase as compared to the SF-JR.
• By setting the slip amount adjustment mode, the frequency command can be adjusted to keep the rotations per minute of
the SF-PR equivalent to those of the SF-JR for power consumption reduction.
Pr.
673
G060
674
G061
• By setting the number of SF-PR motor poles in Pr.673 SF-PR slip amount adjustment operation selection, the SF-PR
slip amount adjustment mode is activated.
• The SF-PR slip amount adjustment mode is available only under V/F control.
• Use Pr.674 SF-PR slip amount adjustment gain to fine-tune the rotations per minute. To reduce the rotations per minute
(to increase the compensation frequency), set a larger value in Pr.674. To increase the rotations per minute (to reduce the
compensation frequency), set a smaller value in Pr.674. (Lower rotations per minute reduce the power consumption, and
higher rotations per minute increase the power consumption.)
NOTE
• The slip amount adjustment is not available in the following conditions.
During acceleration/deceleration, during DC injection brake operation, during PID control, during stall prevention operation,
during regeneration avoidance operation, during traverse operation, and while the slip compensation is valid (Pr.245).
• The slip amount adjustment is not available when the applicable motor capacity of the inverter is not compatible with the SF-
PR. (For details on applicable motor capacity, refer to
Downloaded from
ManualsNet.com
page
voltagepage 552
voltagepage 560
frequency)page 558
selectionpage 557
motorpage 379
Name
SF-PR slip amount
adjustment operation
selection
SF-PR slip amount
adjustment gain
search engine
" is generated when the same frequency value is used for multiple points.
382.)
Initial value
Setting range
2, 4, 6
9999
9999
100%
0% to 500%
page
638.)
Description
Set the number of poles of the SF-PR.
The slip amount adjustment is disabled.
Setting is available for fine adjustment of the slip amount.
5.13 (G) Control parameters
1
2
3
4
5
6
7
8
9
10
559