• FR-F820-00770(18.5K) or higher, FR-F840-00470(22K) or higher
(a) Remove the upper screws.
(b) Remove the lower screws.
(c) Pull the jumper toward you to remove.
(d) Connect the separate power cable for the control circuit to the upper terminals (R1/L11, S1/L21).
Downloaded from
ManualsNet.com
R1/L11 S1/L21
Power supply
terminal block
for the control circuit
R/L1 S/L2 T/L3
MC
Main power supply
FR-F820-00770(18.5K)
to 01250(30K)
FR-F840-00470(22K),
00620(30K)
Power supply
terminal block for
the control circuit
search engine
(c)
Power supply terminal block
for the control circuit
(a)
(b)
(d)
FR-F820-01540(37K)
FR-F820-01870(45K) or higher
FR-F840-00770(37K)
FR-F840-00930(45K) or higher
R1/L11
S1/L21
2. INSTALLATION AND WIRING
2.6 Control circuit
1
2
3
4
5
6
7
8
9
10
71