Function
Pr.
390
414
415
416
417
450
453
454
455
456
457
458
459
460
461
462
463
495
496
497
498
502
503
504
505
506
507
Downloaded from
ManualsNet.com
Pr.
Name
group
% setting reference
N054
frequency
PLC function operation
A800
selection
Inverter operation lock mode
A801
setting
A802
Pre-scale function selection
A803
Pre-scale setting value
C200
Second applied motor
C201
Second motor capacity
Number of second motor
C202
poles
Second motor excitation
C225
current
C204
Rated second motor voltage
Rated second motor
C205
frequency
C220
Second motor constant (R1)
C221
Second motor constant (R2)
Second motor constant (L1) /
C222
d-axis inductance (Ld)
Second motor constant (L2) /
C223
q-axis inductance (Lq)
C224
Second motor constant (X)
Second motor auto tuning
C210
setting/status
M500
Remote output selection
M501
Remote output data 1
M502
Remote output data 2
PLC function flash memory
A804
clear
Stop mode selection at
N013
communication error
E710
Maintenance timer 1
Maintenance timer 1 warning
E711
output set time
M001
Speed setting reference
Display estimated main
*14
E705
circuit capacitor residual life
Display/reset ABC1 relay
E706
contact life
search engine
Minimum
Setting range
setting
increments
1 to 590 Hz
0.01 Hz
0 to 2, 11, 12
1
0, 1
1
0 to 5
1
0 to 32767
1
0, 1, 3 to 6, 13 to 16,
20, 23, 24, 40, 43, 44,
50, 53, 54, 70, 73, 74,
210, 213, 214, 240,
1
243, 244, 8090, 8093,
8094, 9090, 9093,
9094, 9999
*2
0.4 to 55 kW, 9999
0.01 kW
*3
*3
0 to 3600 kW, 9999
0.1 kW
2, 4, 6, 8, 10, 12, 9999 1
*2
*2
0 to 500 A, 9999
0.01 A
*3
*3
0 to 3600 A, 9999
0.1 A
0 to 1000 V
0.1 V
10 to 400 Hz, 9999
0.01 Hz
*2
0 to 50 Ω, 9999
0.001 Ω
*3
0 to 400 mΩ, 9999
0.01 mΩ
*2
0 to 50 Ω, 9999
0.001 Ω
*3
0 to 400 mΩ, 9999
0.01 mΩ
*2
0 to 6000 mH, 9999
0.1 mH
*3
0 to 400 mH, 9999
0.01 mH
*2
0 to 6000 mH, 9999
0.1 mH
*3
0 to 400 mH, 9999
0.01 mH
*2
0.1%
0% to 100%, 9999
*3
0.01%
0, 1, 11, 101
1
0, 1, 10, 11
1
0 to 4095
1
0 to 4095
1
0, 9696 (0 to 9999)
1
0 to 4
1
0 (1 to 9998)
1
0 to 9998, 9999
1
1 to 590 Hz
0.01 Hz
(0% to 100%)
1%
0% to 100%
1%
Initial value
Refer
Customer
to page
FM
CA
60 Hz 50 Hz
533
0
483
0
483
0
483
1
483
9999
379
*2
383,
9999
392
383,
9999
392
9999
383
*7
200 V
383,
392
*8
400 V
383,
9999
392
383,
*2
9999
392,
*3
474
*2
9999
383
*3
*2
383,
9999
392
*3
*2
383,
9999
392
*3
9999
383
383,
0
392,
474
0
341
0
341
0
341
0
483
0
500
0
224
9999
224
60 Hz 50 Hz
303
100%
220
100%
220