Download Print this page

Mitsubishi Electric FR-F800 Series Instruction Manual page 639

Hide thumbs Also See for FR-F800 Series:

Advertisement

8
SPECIFICATIONS
This chapter explains the specifications of this product.
Always read the instructions before use.
For the separated converter type inverter, refer to "SPECIFICATIONS" in the FR-F802 (Separated Converter Type) Instruction
Manual (Hardware).
For the IP55 compatible model inverter, refer to "SPECIFICATIONS" in the FR-F806 (IP55/UL Type12 specification) Instruction
Manual (Hardware).
8.1
Inverter rating
 200 V class
Model FR-F820-[]
Applicable motor
SLD
*1
capacity (kW)
LD
Rated
SLD
capacity
LD
*2
(kVA)
SLD
Rated current
(A)
LD
Overload
SLD
current
LD
*3
rating
*4
Rated voltage
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Without DC
reactor
Rated input
*5
current (A)
With DC
reactor
Without DC
Power supply
reactor
capacity
With DC
*6
(kVA)
reactor
Protection rating of structure (IEC
*7
60529)
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric standard 4-pole motor.
*2
The rated output capacity is the value with respect to 220 V output voltage.
*3
The percentage of the overload current rating is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow
time for the inverter and motor to return to or below the temperatures under 100% load.
*4
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about
*5
The rated input current is the value at a rated output voltage. The input power impedances (including those of the input reactor and cables) affect
the value.
*6
The power supply capacity is the value at the rated output current. The input power impedances (including those of the input reactor and cables)
affect the value.
*7
FR-DU08: IP40 (except for the PU connector)
638
8. SPECIFICATIONS
8.1 Inverter rating
Downloaded from
ManualsNet.com
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
0.75K 1.5K 2.2K 3.7K 5.5K 7.5K
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
1.8
2.9
4
6.4
1.6
2.7
3.7
5.8
4.6
7.7
10.5
16.7
4.2
7
9.6
15.2
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
Three-phase 200 to 240 V
Three-phase 200 to 240 V, 50/60 Hz
170 to 264 V, 50/60 Hz
±5%
SLD
5.3
8.9
13.2
19.7
LD
5
8.3
12.2
18.3
SLD
4.6
7.7
10.5
16.7
LD
4.2
7
9.6
15.2
SLD
2
3.4
5
7.5
LD
1.9
3.2
4.7
7
SLD
1.8
2.9
4
6.4
LD
1.6
2.7
3.7
5.8
Enclose type (IP20)
Natural
Forced air
1.9
2.1
3.1
3.1
search engine
11K
15K 18.5K 22K
5.5
7.5
11
15
18.5
22
5.5
7.5
11
15
18.5
22
10
13
19
24
29
35
8.8
12
17
22
27
32
25
34
49
63
77
93
23
31
45
58
70.5
85
31.3
45.1
62.8
80.6
96.7
115
28.5
41.6
58.2
74.8
90.9
106
25
34
49
63
77
93
23
31
45
58
71
85
12
17
24
31
37
44
11
16
22
29
35
41
10
13
19
24
29
35
8.8
12
17
22
27
32
3.1
6.3
6.3
8.3
15.5
15.5
30K
37K
45K
55K
75K
90K 110K
90/
30
37
45
55
75
110
30
37
45
55
75
90
48
59
71
89
120
145
43
53
65
81
110
132
125
154
187
233
316
380
114
140
170
212
288
346
151
185
221
269
139
178
207
255
125
154
187
233
316
380
114
140
170
212
288
346
58
70
84
103
53
68
79
97
48
59
71
89
120
145
43
53
65
81
110
132
Open type (IP00)
15.5
22
42
42
54
74
132
110
181
165
475
432
475
432
181
165
74
.

Advertisement