Download Print this page

Mitsubishi Electric FR-F800 Series Instruction Manual page 157

Hide thumbs Also See for FR-F800 Series:

Advertisement

Function
Pr.
738
739
740
741
742
743
744
745
746
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
774
775
776
777
778
779
791
156
5. PARAMETERS
5.1 Parameter list
Downloaded from
ManualsNet.com
Pr.
Name
group
Second motor induced
C230
voltage constant (phi f)
C231
Second motor Ld decay ratio 0% to 100%, 9999
C232
Second motor Lq decay ratio 0% to 100%, 9999
Second starting resistance
C282
tuning compensation
Second motor magnetic pole
C285
detection pulse width
Second motor maximum
C206
frequency
Second motor inertia
C207
(integer)
Second motor inertia
C208
(exponent)
Second motor protection
C233
current level
A650
Second PID action selection
Second PID control
A652
automatic switchover
frequency
A651
Second PID action set point
Second PID proportional
A653
band
A654
Second PID integral time
A655
Second PID differential time
A600
PID unit selection
A616
Pre-charge fault selection
A617
Pre-charge ending level
A618
Pre-charge ending time
Pre-charge upper detection
A619
level
A620
Pre-charge time limit
Second pre-charge fault
A656
selection
Second pre-charge ending
A657
level
Second pre-charge ending
A658
time
Second pre-charge upper
A659
detection level
A660
Second pre-charge time limit 0 to 3600 s, 9999
Operation panel monitor
M101
selection 1
Operation panel monitor
M102
selection 2
Operation panel monitor
M103
selection 3
A681
4 mA input fault operation
frequency
T053
A682
4 mA input check filter
T054
Operation frequency during
N014
communication error
Acceleration time in low-
F070
speed range
search engine
Minimum
Setting range
setting
increments
0 to 5000 mV (rad/s),
0.1 mV
9999
(rad/s)
0.1%
0.1%
0% to 200%, 9999
0.1%
0 to 6000 μs, 10000 to
1 μs
16000 μs, 9999
0 to 400 Hz, 9999
0.01 Hz
10 to 999, 9999
1
0 to 7, 9999
1
100% to 500%, 9999
0.1%
0, 10, 11, 20, 21, 50,
51, 60, 61, 70, 71, 80,
81, 90, 91, 100, 101,
1
1000, 1001, 1010,
1011, 2000, 2001,
2010, 2011
0 to 590 Hz, 9999
0.01 Hz
0% to 100%, 9999
0.01%
0.1% to 1000%, 9999
0.1%
0.1 to 3600 s, 9999
0.1 s
0.01 to 10 s, 9999
0.01 s
0 to 43, 9999
1
0, 1
1
0% to 100%, 9999
0.1%
0 to 3600 s, 9999
0.1 s
0% to 100%, 9999
0.1%
0 to 3600 s, 9999
0.1 s
0, 1
1
0% to 100%, 9999
0.1%
0 to 3600 s, 9999
0.1 s
0% to 100%, 9999
0.1%
0.1 s
1
1 to 3, 5 to 14, 17, 18,
20, 23 to 25, 34, 38, 40
1
to 45, 50 to 57, 61, 62,
64, 67 to 69, 81 to 96,
98, 100, 9999
1
0 to 590 Hz, 9999
0.01 Hz
0 to 10 s
0.01 s
0 to 590 Hz, 9999
0.01 Hz
0 to 3600 s, 9999
0.1 s
Initial value
Refer
Customer
to page
setting
FM
CA
9999
392
9999
392
9999
392
9999
392
9999
392
9999
392
9999
392
9999
392
9999
392
0
419
9999
419
9999
419
100%
419
1 s
419
9999
419
9999
442
0
445
9999
445
9999
445
9999
445
9999
445
0
445
9999
445
9999
445
9999
445
9999
445
305,
9999
533
305,
9999
533
305,
9999
533
9999
369
0 s
369
9999
500
9999
228

Advertisement