4.3 Setting the parameters

4.3.1
Example: Changing the Pr. 7 setting from "5s" to "10s"
(For parameter details, refer to the instruction manual (detailed).)
Operation
1.
Confirm the RUN indication and
operation mode indication.
The inverter must be at a stop.
The inverter must be in the PU
operation mode.
2.
Press the
to choose
MODE
the parameter setting mode.
3.
Turn the
until the desired
parameter number appears.
Example: Pr. 7 "acceleration time"
4.
Press the
to read the currently
SET
set value.
Example: "5" (factory setting) appears.
5.
Turn the
until the desired value
appears.
Example: To change setting from
"5" to "10".
6.
Press the
to set the value.
SET
By turning the
Press the
Press the
After parameter setting is complete, press the
history or twice to return to the monitor display.
another parameter, perform the operation in above steps 3 to 6.
Error display?
Remarks
If the setting has not been changed, the value does not flicker and the next parameter
number appears.
Either step 1 or 2 may be carried out first.
Convenient usage
After carrying out steps 1 and 2 to choose the parameter setting mode, you can read a series
of parameter numbers in due order every time you press the
(Press the
.)
PU
EXT
Flicker...Parameter setting complete!!
, you can read another parameter.
SET
to show the setting again.
twice to show the next parameter.
SET
• If write was performed with "1" set in Pr. 77
• If the operation panel does not have the write precedence
• If write was performed during operation
• If write was performed in the external operation mode
Display
MODE
SET
SET
once to show the alarm
MODE
To change the setting of
SET
21
Setting the parameters
RUN
PU
EXT
The parameter
number read
previously
appears.
.