Download Print this page

Mitsubishi Electric FR-F800 Series Instruction Manual page 470

Hide thumbs Also See for FR-F800 Series:

Advertisement

 Restart operation with frequency search (Pr.162 = "0, 2, 3, 10, 12, 13, 1000,
1002, 1003, 1010, 1012, or 1013", Pr.299)
• When Pr.162 = "0 (initial value), 2, 3, 10, 12, 13, 1000, 1002, 1003, 1010, 1012, or 1013", the motor speed is detected at
a power restoration so that the motor can re-start smoothly.
• The encoder also detects the rotation direction so that the inverter can re-start smoothly even during the reverse rotation.
• Whether or not to detect the rotation direction can be selected by Pr.299 Rotation direction detection selection at
restarting.
If the motor capacity is different from the inverter capacity, set Pr.299 = "0" (no rotation direction detection).
• When the rotation direction is detected, the following operation is performed according to Pr.78 Reverse rotation
prevention selection setting.
Pr.299 setting
9999 (initial value)
0
1
• By setting "3, 13, 1003, or 1013" in Pr.162, the restart can be made smoother with even less impact than when "0, 2, 10,
12, 1000, 1002, 1010, or 1012" is set in Pr.162.
When the inverter is restarted with "3, 13, 1003, or 1013" set in Pr.162, offline auto tuning is required. (For details on offline
auto tuning of Advanced magnetic flux vector control, refer to
refer to
page
V/F control, Advanced magnetic flux vector control
Power supply
(R/L1, S/L2,
T/L3)
Motor speed N
(r/min)
Inverter output
frequency f(Hz)
Inverter output
voltage E(V)
Coasting
time (Pr.57)
* The output shut off timing differs
according to the load condition.
NOTE
• The rotation speed detection time (frequency search) changes according to the rotation speed of the motor. (maximum 1
second)
• When the inverter capacity is two ranks or greater than the motor capacity, the overcurrent protective function (E.OC[]) is
sometimes activated and prevents the inverter from restarting.
• If two or more motors are connected to one inverter, this function operates abnormally. (The inverter does not restart
successfully.)
• Because a DC injection brake is applied instantaneously at speed detection during a restart, the speed might drop if the
moment of inertia (J) of the load is small.
• If reverse operation is detected when "1" (reverse rotation disabled) is set to Pr.78, operation decelerates by reverse rotation
and then changes to forward rotation when the start command is forward rotation. The inverter does not restart when the start
command is reverse rotation.
• When "3, 13, 1003, or 1013" is set to Pr.162, limit the wiring length to within 100 m.
Downloaded from
ManualsNet.com
×
474.)
Instantaneous (power failure) time
*
Restart cushion
Speed
time (Pr.58 setting)
detection
+
time
Acceleration time
at a restart
(Pr.611 setting)
search engine
Pr.78 setting
0
×
×
○: With rotation direction detection ×: Without rotation direction detection
page
383, and for details on offline auto tuning of V/F control,
1
×
×
5. PARAMETERS
5.11 (A) Application parameters
1
2
3
4
2
5
6
7
8
9
10
469

Advertisement

loading