Download Print this page

Mitsubishi Electric FR-F800 Series Instruction Manual page 684

Hide thumbs Also See for FR-F800 Series:

Advertisement

Pr.
PID lower limit operation detection
1346
time
1361 Detection time for PID output hold
1362 PID output hold range
1363 PID priming time
1364 Stirring time during sleep
1365 Stirring interval time
1366 Sleep boost level
1367 Sleep boost waiting time
1368 Output interruption cancel time
Check valve closing completion
1369
frequency
Detection time for PID limiting
1370
operation
PID upper/lower limit pre-warning
1371
level range
PID measured value control set point
1372
change amount
PID measured value control set point
1373
change rate
Auxiliary pressure pump operation
1374
starting level
Auxiliary pressure pump operation
1375
stopping level
1376 Auxiliary motor stopping level
1377 PID input pressure selection
1378 PID input pressure warning level
1379 PID input pressure fault level
PID input pressure warning set point
1380
change amount
PID input pressure fault operation
1381
selection
MC switchover interlock time (for
phase-synchronized bypass
1382
switching function)
Phase compensation amount for
1383
synchronous bypass switching
1384 PLL tuning gain
1410 Starting times lower 4 digits
1411 Starting times upper 4 digits
Motor induced voltage constant (phi
1412
f) exponent
Second motor induced voltage
1413
constant (phi f) exponent
1442 IP filter address 1 (Ethernet)
1443 IP filter address 2 (Ethernet)
1444 IP filter address 3 (Ethernet)
1445 IP filter address 4 (Ethernet)
IP filter address 2 range
1446
specification (Ethernet)
IP filter address 3 range
1447
specification (Ethernet)
IP filter address 4 range
1448
specification (Ethernet)
1459 Clock source selection
1460 PID multistage set point 1
1461 PID multistage set point 2
1462 PID multistage set point 3
1463 PID multistage set point 4
Downloaded from
ManualsNet.com
Name
Read Write Extended
2E
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
0 A
0B
0C
0D
2A
2B
2C
2D
2E
2F
30
3B
3C
3D
3E
3F
search engine
*1
Instruction code
V/F
V/F
V/F
AE
D
BD
D
BE
D
BF
D
C0
D
C1
D
C2
D
C3
D
C4
D
C5
D
C6
D
C7
D
C8
D
C9
D
CA
D
CB
D
CC
D
CD
D
CE
D
CF
D
D0
D
D1
D
D2
D
D3
D
D4
D
8A
E
8B
E
8C
E
×
8D
E
×
AA
E
AB
E
AC
E
AD
E
AE
E
AF
E
B0
E
BB
E
BC
E
BD
E
BE
E
BF
E
9.5 Parameters (functions) and instruction codes under different control methods
*2
Control method
Copy
Magnetic flux
Magnetic flux
Magnetic flux
PM
PM
PM
×
×
×
×
×
Parameter
1
All
*3
*3
Clear
*3
clear
2
3
4
5
6
7
8
9
10
×
×
×
×
×
×
×
×
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
683
9. APPENDIX

Advertisement

loading