Monitor item
PLC function user
monitor 1
PLC function user
monitor 2
PLC function user
monitor 3
Station number (RS-
485 terminals)
Station number (PU)
Station number (CC-
Link)
Power saving effect
Cumulative energy
saving
PID set point
PID measured value
PID deviation
Input terminal status
Output terminal
status
Option input terminal
*10
status
Option output
*10
terminal status
Option input terminal
status 1 (for
communication)
Option input terminal
status 2 (for
communication)
Option output
terminal status (for
communication)
Motor thermal load
factor
Inverter thermal load
factor
PTC thermistor
resistance
PID measured value
2
Emergency drive
*8
status
Downloaded from
ManualsNet.com
Increment
Pr.
and unit
setting
40
Increment set
41
in the register
SD1215
42
1
43
1
44
1
45
Increment
50
and unit vary
depending on
51
the parameter
settings.
0.1%
52
0.1%
53
0.1%
54
*18
55
56
57
*10
*10
*10
0.1%
61
0.1%
62
0.01 kΩ
64
0.1%
67
1
68
search engine
Negative
MODBUS
RS-485
indication
RTU
*1
(-)
H28
40240
H29
40241
H2A
40242
H2B
40243
H2C
40244
H2D
40245
H32
40250
H33
40251
H34
40252
H35
40253
H36
40254
*11
*11
H0F
40215
*12
*12
H10
40216
*13
*13
H3A
40258
*14
*14
H3B
40259
*15
*15
H3C
40260
H3D
40261
H3E
40262
H40
40264
H43
40267
H44
40268
Description
The user-designated monitor item is displayed using the
PLC function.
Each value of the following special registers is displayed.
SD1216: displayed with the setting value "40"
SD1217: displayed with the setting value "41"
SD1218: displayed with the setting value "42"
(Refer to the PLC Function Programming Manual.)
The station number (0 to 31) of the inverter enabling
communication via the RS-485 terminals is displayed.
The station number (0 to 31) of the inverter enabling
communication via the PU connector is displayed.
The station number of the inverter enabling CC-Link
communication is displayed. ("0" is displayed when the
FR-A8NS is not installed.)
The energy saving effect monitoring is enabled. The item
to monitor is selectable from among the saved power, the
average energy saving, and the energy cost savings.
Some of them can be displayed as a percentage
according to the parameter settings. (Refer to
The set point, measured value, and deviation during PID
control operation is displayed. (Refer to
The ON/OFF state of the input terminals on the inverter
is displayed. (Refer to
page 310
on the DU.)
The ON/OFF state of the output terminals on the inverter
is displayed. (Refer to
page 310
on the DU.)
The ON/OFF state of the input terminals on the digital
input option (FR-A8AX) is displayed on the DU. (Refer to
page 310
for details.)
The ON/OFF state of the output terminals on the digital
output option (FR-A8AY) or the relay output option (FR-
A8AR) is displayed on the DU. (Refer to
details.)
The ON/OFF state of the input terminals X0 to X15 on the
digital input option (FR-A8AX) is monitored via RS-485
communication or other communication when the
communication option is installed.
The ON/OFF state of the input terminal DY on the digital
input option (FR-A8AX) is monitored via RS-485
communication or other communication when the
communication option is installed.
The ON/OFF state of the output terminals on the digital
output option (FR-A8AY) or the relay output option (FR-
A8AR) is monitored via RS-485 communication or other
communication when the communication option is
installed.
The accumulated heat value of the motor thermal O/L
relay is displayed.
The motor overload trip (electronic thermal relay
function) (E.THM) occurs at 100%.
The accumulated heat value of the inverter thermal O/L
relay is displayed.
The inverter overload trip (electronic thermal relay
function) (E.THT) occurs at 100%.
The PTC thermistor resistance is displayed when Pr.561
PTC thermistor protection level ≠ 9999. (The output
voltage is displayed when Pr.561 = 9999.)
The PID measured value is displayed while the PID
control is enabled (Pr.128 ≠ "0"), even if PID control
operating conditions are not satisfied. (Refer to
432.)
Displays the emergency drive status. (Refer to
279.)
5.8 (M) Item and output signal for monitoring
1
2
3
4
5
page
324.)
6
page
432.)
7
for details of indication
8
for details of indication
9
page 310
for
10
page
page
307
5. PARAMETERS