Mitsubishi Electric FR-F800 Series Instruction Manual page 385

Hide thumbs Also See for FR-F800 Series:

Advertisement

Pr.
Name
450
Second applied
C200
motor
453
Second motor
C201
capacity
Number of
454
second motor
C202
poles
51
Second electronic
C203
thermal O/L relay
456
Rated second
C204
motor voltage
457
Rated second
C205
motor frequency
744
Second motor
C207
inertia (integer)
745
Second motor
C208
inertia (exponent)
Second motor
463
auto tuning
C210
setting/status
458
Second motor
C220
constant (R1)
459
Second motor
C221
constant (R2)
Second motor
460
constant (L1) / d-
C222
axis inductance
(Ld)
Second motor
461
constant (L2) / q-
C223
axis inductance
(Lq)
462
Second motor
C224
constant (X)
455
Second motor
C225
excitation current
Second motor
860
torque current/
C226
Rated PM motor
current
Second
560
frequency search
A712
gain
*1
For the FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower.
*2
For the FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher.
*3
The initial value differs according to the voltage class (200 V / 400 V).
*4
The setting range and unit change according to the Pr.71 (Pr.450) setting.
384
5. PARAMETERS
5.10 (C) Motor constant parameters
Downloaded from
ManualsNet.com
Initial
Setting range
value
0, 1, 3 to 6, 13 to 16, 20, 23,
24, 40, 43, 44, 50, 53, 54,
70, 73, 74, 210, 213, 214,
9999
240, 243, 244, 8090, 8093,
8094, 9090, 9093, 9094
9999
0.4 to 55 kW
9999
0 to 3600 kW
9999
2, 4, 6, 8, 10, 12
9999
9999
0 to 500 A
9999
0 to 3600 A
9999
*3
0 to 1000 V
200/400 V
10 to 400 Hz
9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
0
1
0
11
101
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
0 to 6000 mH, 9999
9999
0 to 400 mH, 9999
0 to 6000 mH, 9999
9999
0 to 400 mH, 9999
9999
0 to 100%, 9999
0 to 500 A, 9999
9999
0 to 3600 A, 9999
0 to 500 A, 9999
9999
0 to 3600 A, 9999
0 to 32767
9999
9999
search engine
Set this parameter when using the second motor
(the same specifications as Pr.71).
The function is disabled.
*1
Set the capacity of the second motor.
*2
V/F control
Set the number of poles of the second motor.
V/F control
*1
This function is enabled when the RT signal is ON.
Set the rated motor current.
*2
Second electronic thermal O/L relay disabled.
Set the rated voltage (V) of the second motor.
Set the rated frequency (Hz) of the second motor.
The Pr.84 Rated motor frequency setting is used.
Set the inertia of the second motor.
9999: The constant value of Mitsubishi Electric motor (SF-PR,
SF-JR, SF-HR, SF-JRCA, SF-HRCA and so on) is used.
No auto tuning for the second motor.
Offline auto tuning is performed without the second motor
rotating.
Offline auto tuning is performed without the motor rotating (V/F
control, IPM motor MM-EFS/MM-THE4). (Refer to
Offline auto tuning is performed with the second motor rotating.
*1*4
*2*4
*1*4
*2*4
*1*4
*2*4
Tuning data of the second motor
*1*4
(The value measured by offline auto tuning is automatically
set.)
*2*4
9999: The constant value of Mitsubishi Electric motor (SF-PR,
SF-JR, SF-HR, SF-JRCA, SF-HRCA and so on) is used.
*4
*1*4
*2*4
*1*4
*2*4
The offline auto tuning automatically sets the gain required for
the frequency search of the second motor.
The constant value of Mitsubishi Electric motor (SF-PR, SF-JR,
SF-HR, SF-JRCA, SF-HRCA and so on) is used for the second
motor.
Description
page
474.)