Parameters
5.7

(E) Environment setting parameters

Purpose
To set the time
To set a limit for the reset function.
To shut off output if the operation panel
disconnects.
To force deceleration to a stop on the
operation panel.
To select the display language of the
parameter unit
To control the buzzer of the parameter
unit and operation panel
To adjust the LCD contrast of the
parameter unit
To turn OFF the operation panel when
not using it for a certain period of time
To use the USB memory
To use the setting dial of the operation
panel like a potentiometer to set the
frequency.
To disable the operation panel.
To change the frequency change
increments which changes when using
the setting dial of the operation panel
To use the regeneration unit to increase
the motor braking torque
To change the overload current rating
specification
To input a voltage between 480 V and
500 V
To prevent parameter rewriting
To restrict parameters with a password
To use parameters freely
To change parameter settings for an IPM
motor as a batch
To set multiple parameters as a batch
To display the required parameters
To release the parameter copy warning
(CP)
To reduce the motor noise and EMI
To understand the maintenance time of
inverter parts and peripheral device
FR-A800
Parameter to set
Real time clock function
P.E020 to P.E022
Reset selection/
disconnected PU
P.E100 to P.E102,
detection/PU stop
P.E107
selection/Reset limit
PU display language
P.E103
selection
PU buzzer control
P.E104
PU contrast adjustment
P.E105
Display-off mode
P.E106
USB host reset
P.E110
Operation panel
P.E200
operation selection
Frequency change
P.E201
increment amount setting
Regenerative brake
P.E300, P.G107
selection
Multiple rating setting
P.E301
Input voltage mode
P.E302
selection
Parameter write disable
P.E400
selection
Password function
P.E410, P.E411
Free parameter
P.E420, P.E421
IPM parameter
P.E430
initialization
Automatic parameter
P.E431
setting
Applicable parameter
display and user group
P.E440 to P.E443
function
Parameter copy alarm
P.E490
release
PWM carrier frequency
P.E600 to P.E602
changing
Inverter parts life display
P.E700 to P.E704
Maintenance output
P.E710 to P.E715
function
Current average value
P.E720 to P.E722
monitor signal
(E) Environment setting parameters
Pr. 1006 to Pr. 1008
Pr. 75
Pr. 145
Pr. 990
Pr. 991
Pr.1048
Pr. 1049
Pr. 161
Pr. 295
Pr. 30, Pr. 70
Pr. 570
Pr. 977
Pr. 77
Pr. 296, Pr. 297
Pr. 888, Pr. 889
Pr. 998
Pr. 999
Pr. 160,
Pr. 172 to Pr. 174
Pr. 989
Pr. 72, Pr. 240,
Pr. 260
Pr. 255 to Pr. 259
Pr. 503, Pr. 504,
Pr. 686 to Pr. 689
Pr. 555 to Pr. 557
Refer to
page
5-198
5-200
5-204
5-204
5-204
5-205
5-205
5-206
5-208
5-713
5-209
5-211
5-211
5-215
5-219
5-76
5-219
5-224
5-740
5-227
5-230
5-235
5-237
5 - 197