Download Print this page

Terminal Connection Diagrams - Mitsubishi Electric FR-F800 Series Instruction Manual

Hide thumbs Also See for FR-F800 Series:

Advertisement

2.4
 Type FM
Sink logic
Main circuit terminal
Control circuit terminal
Three-phase
AC power
supply
Control input signals
(No voltage input allowed) 
Forward rotation start
Reverse rotation start
Start self-holding selection
High speed
Multi-speed
Middle speed
selection
Low speed
Jog operation
Second function selection
Output stop
Terminal 4 input selection
(Current input selection)
Contact input common
(Common for external power supply transistor)
24V external power
Common terminal
Frequency setting signals (Analog)
Frequency setting
potentiometer
1/2W1kΩ 
Auxiliary
input
Terminal 4 input
(Current input)
Connector for plug-in option connection
Safety stop signal
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common
Downloaded from
ManualsNet.com

Terminal connection diagrams

DC reactor
(FR-HEL) 
Jumper
Earth
(Ground)
P1
MC
MCCB
R/L1
S/L2
T/L3
R1/L11
Jumper

S1/L21
Earth
(Ground)
Control circuit
STF
STR
STP(STOP)
RH
RM
RL

JOG
RT
MRS
RES
Reset
AU
CS

SD
PC
24VDC power supply
+24
supply input
SD
10E(+10V)
10(+5V)
3
DC0 to 5V
2
2
DC0 to 10V selectable
DC0 to 20mA
1
5
(Analog common)
DC0 to ±10V
(+)
1
DC0 to ±5V selectable
(-)
DC4 to 20mA
(+)
4
DC0 to 5V
(-)
DC0 to 10V
Connector 1 Connector 2
Connector 3
Shorting
24V
wire
PC
S1
S2
Output shutoff
circuit
SIC
SD
search engine
Brake unit
(Option)
Jumper 
P/+
PX  PR  N/-
U
Inrush current
V
limit circuit
W
ON
EMC filter
ON/OFF
connecter
OFF
Main circuit
C1
B1
A1
C2
B2
A2
RUN
Running
SU
Up to frequency
IPF
Instantaneous
power failure
OL
Overload
FU
Frequency detection
SE
24V
PU
connector
Voltage/current

input switch
F/C
ON
USB A
OFF
(FM)

connector
2
4
Initial value
SD

USB
mini B
AM
connector
5
Initial value

TXD+
Initial value
TXD-
selectable

RXD+
RXD-
GND
(SG)
Terminating
VCC
resistor
So (SO)
SOC
FR-F820-00770(18.5K) to 01250(30K),
FR-F840-00470(22K) to 01800(75K)
DC reactor
(FR-HEL) 
Jumper
Earth

(Ground)
P1
P/+
P3
Inrush
current
limit circuit
Motor
M
Earth (Ground)
Relay output 
Relay output 1
(Fault output)
Relay output 2
Open collector output 
Open collector output common
Sink/source common
Indicator
+
-
(Frequency meter, etc.)
Calibration
Moving-coil type
resistor 
1mA full-scale
(+) Analog signal output
(0 to ±10VDC)
(-)
RS-485 terminals
Data
transmission
Data
reception
GND
5V
(Permissible load current 100mA)
Safety monitor output
Safety monitor output common
2. INSTALLATION AND WIRING
2.4 Terminal connection diagrams
1
2
3
Brake unit
(Option)
4
PR  N/-
5
6
7
8
9
10
45

Advertisement

loading