Download Print this page

Mitsubishi Electric FR-F800 Series Instruction Manual page 628

Hide thumbs Also See for FR-F800 Series:

Advertisement

 Replacement procedure of the cooling fan
The replacement interval of the cooling fan used for cooling the parts generating heat such as the main circuit semiconductor
is greatly affected by the surrounding air temperature. When unusual noise and/or vibration are noticed during inspection, the
cooling fan must be replaced immediately.
 Removal (FR-F820-00105(2.2K) to 04750(110K), FR-F840-00083(3.7K) to 03610(160K))
1.
Push the hooks from above and remove the fan cover.
FR-F820-00105(2.2K) to 00250(5.5K)
FR-F840-00083(3.7K), 00126(5.5K)
2.
Disconnect the fan connectors.
3.
Remove the fan.
FR-F820-00105(2.2K) to 00250(5.5K)
FR-F840-00083(3.7K), 00126(5.5K)
*1
The number of cooling fans differs according to the inverter capacity.
Downloaded from
ManualsNet.com
FR-F820-00340(7.5K) to 01540(37K)
FR-F840-00170(7.5K) to 00770(37K)
Fan cover
Fan
FR-F820-00340(7.5K) to 01540(37K)
FR-F840-00170(7.5K) to 00770(37K)
search engine
FR-F820-01870(45K) or higher
FR-F840-00930(45K) to 03610(160K)
Fan cover
Fan connection
connector *1
FR-F820-01870(45K) or higher
FR-F840-00930(45K) to 03610(160K)
7. PRECAUTIONS FOR MAINTENANCE AND INSPECTION
1
2
3
4
5
6
7
Fan cover
8
Fan connection
connector
9
10
627
7.1 Inspection item

Advertisement

loading