13-22 Routine maintenance procedures
Battery replacement
Battery replacement
OPAC
OPAC
(continued)
(end)
At the MAP terminal
10
10
11 Disp_
12 Next
13
14 QueryPES
15 OpenCkt_
16 Charge_
17 LoadB_
18 MEASure_
11
12
297-8211-550 Standard 05.01 August 1999
To return the battery strings to the load bus, type
>LOADB n
and press the Enter key.
where
n
is the string pair 0–2, as follows:
0
is pair 0,4
1
is pair 1,5
2
is pair 2,6
Example of a MAP display:
CM
MS
IOD
NET
.
.
.
OPMPES
0 Quit
PM
2 Post_
3
4
OPMPES
5
6 Tst_
OPMPES
7 Bsy_
8 Rts_
Common
9 OffL_
AC
.
BCC
0
0= W
.
1= W
.
To activate the automatic battery rotation and testing, type
>AUDIT ENABLE
and press the Enter key.
This procedure is complete.