Summary of card replacement procedure for an NT6X17 card in an LCM
At LTP level, post
the line
Is the
linestatus
ManB?
N
Busy the line
Replace the line
card
Test the line
Did test pass?
N
Obtain assistance
from maintenance
support group
Y
Y
Return the line to
service
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-63
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Y
Did return to
service pass?
N
Obtain assistance
from maintenance
support group
NT6X17
LCM
(continued)
End of procedure