Nortel DMS-100 Series Maintenance Manual page 353

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8
To busy the scan card, type
>BSY PESALRM
and press the Enter key.
The letter M appears under PESALRM on the MAP display.
Example of a MAP display:
CM
MS
IOD
.
.
.
OPMPES
SysB
0 Quit
PM
2 Post_
3
4
PES
5
6 Tst_
OPMPES
7 Bsy_
8 Rts_
Common
9 OffL_
AC
10
.
11 Disp_
BCC 0
12 Next
0=w .
13 Audit_
1=w
14 QueryPES
15 OpenCkt_
16 Charge_
17 LoadB_
18 Measure_
9
To test the scan card, type
>TST PESALRM
and press the Enter key.
If test
fails
passes
Replace the scan card (NT0X10). Use the Card Replacement Procedures to
10
replace the card.
Notify outside operating company personnel. Go to step 11.
critical, major, minor
NET
PM
CCS
.
1PES
.
ManB
OffL
0
3
4
RED
0
2 Cond: AMBER
Rectifiers
FL0 FL1 CL0 CL1 BCCDVR PESALRM
.
.
.
.
1
2
3
.
.
-
EHT ELT
.
.
.
-
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Alarm clearing procedures 7-117
LNS
Trks
Ext
.
.
.
CBSY
ISTB
0
4
AMBER
GREEN
1
3
REM2
2
1
Audit
Week
DIS
.
M
Temp
Door
FRNT SIDE
.
.
.
.
Do
step 10
step 12
PMPES
(continued)
Appl
.
InSV
30
OFFL
1
RMM
2
HBT
.
ECU FSP
.
.
BCCFUSES
0
1
.
.

Advertisement

Table of Contents
loading

Table of Contents