7-126 Alarm clearing procedures
ESA
critical, minor
(continued)
6
7
8
9
297-8211-550 Standard 05.01 August 1999
To identify and post the LCM in the OPAC associated with the link that has
defects, type
>POST LCM site frame lcm
and press the Enter key.
where
site is the site name of the OPAC (alphanumeric)
frame
is the frame number of the OPAC (0 to 511)
lcm is the number of the LCM
To identify peripheral-side (P-side) links that have defects associated with ESA,
type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 0: RMM 0
Link 1: RMM 0
Link 2: ESA 0
Link 3: ESA 0
Record information for the ESA links that have a state other than OK.
To busy the link that has defects, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link identified in step 7
To return the busied link to service, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link
If return to service
passes and no other links are SysB
passes and other links are SysB
fails
0;Cap MS;Status:OK
1;Cap MS;Status:OK
0;Cap M ;Status:SysB
1;Cap M ;Status:SysB
Do
step 20
step 8
step 19
;MsgCond:OPN
;MsgCond:OPN
;MsgCond:CLS
;MsgCond:CLS

Advertisement

Table of Contents
loading

Table of Contents