Nortel DMS-100 Series Maintenance Manual page 378

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-12 Card replacement procedures
NT2X06
RMM
(continued)
26
27
28
29
30
31
297-8211-550 Standard 05.01 August 1999
List the SLM file names into your user directory by typing
>LV CM;LF file_name
and pressing the Enter key.
where
file_name
is the name of the SLM disk volume containing the PM load
files obtained in step 24.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Reload the RMM by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
Return the RMM to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 33.
Do
step 32
step 29
Do
step 33
step 32

Advertisement