Nortel DMS-100 Series Maintenance Manual page 550

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-184 Card replacement procedures
NTMX45
HIE
(continued)
28
29
30
297-8211-550 Standard 05.01 August 1999
Query the PM counters for the firmware load on the NTMX45 by typing
>QUERYPM CNTRS
and pressing the Enter key.
Example of a MAP display:
Unsolicitited MSG limit = 250, count = 0
Ram Load: MSA12AM1
EPRom Version: Ac01
EEPRom Load: Loadable:
EP:MX45AA
If firmware is
valid
invalid
Load the NTMX45 firmware by typing
>LOADFW
and pressing the Enter key.
Note: The command applies the firmware file provisioned in table XESAINV
unless the firmware load is indicated with the command.
If load
passes
fails
Upgrade the firmware in the NTMX45AA by typing
>LOADFW UPGRADE
and pressing the Enter key.
If the LOADFW UPGRADE
passes
fails
NP02
, Executable:
NTMX45 Firmware loadname
Do
step 31
step 29
Do
step 30
step 35
Do
step 31
step 35
NP02

Advertisement

Table of Contents
loading

Table of Contents