8-162 Card replacement procedures
NT6X75
HIE
(continued)
7
8
9
At the OPAC
10
11
At the MAP terminal
12
297-8211-550 Standard 05.01 August 1999
Busy the ESA processor by typing
>BSY
and pressing the Enter key.
Example of a MAP response:
This action will take this PM out of service
Please confirm ("Yes" or "No")
Respond by typing
>YES
and pressing the Enter key.
Post the LCM associated with the faulty NT6X75 card by typing
>POST LCM site frame lcm
and pressing the Enter key.
where
site
is the name of the location of the OPAC
frame
is the number of the OPAC cabinet
lcm
is the number of the LCM in the OPAC cabinet
Busy unit 0 by typing
>BSY UNIT 0
and pressing the Enter key.
Replace the NT6X75 card using the procedure "Replacing a card." When you
have completed the procedure, return here.
If you were directed to this procedure from the Alarm Clearing Procedures ,
return now to the alarm clearing procedure that directed you here. Otherwise,
continue with step 12.
Return to service unit 0 by typing
>RTS UNIT 0
and pressing the Enter key.
If RTS
passed
failed
Do
step 13
step 35