28
To attempt to reload the OPAC, type
>LOADPM PM CC
and press the Enter key.
If load
is successful
is not successful
29
For additional information on how to clear this fault, contact the maintenance
support group.
30
Switch the circuit breaker to the OFF position to power down the converter in
the LCM unit of the current OPAC.
Use the following table to determine which modular supervisory panel (MSP)
circuit breaker serves the unit.
If the circuit breaker
is CB01
is CB03
31
Refer to the Card Replacement Procedures section. Replace the first card that
appears on the card list. Notify outside plant personnel before you change the
card. After you replace the card, go to step 30.
32
Switch the circuit breaker to the ON position to power up the converter in the
LCM unit of the current OPAC.
Use the following table to determine which MSP circuit breaker serves the unit.
If the circuit breaker
is CB01
is CB03
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Alarm clearing procedures 7-13
critical
Do
step 25
step 27
The unit
is LCA 0
is LCA 1
The unit
is LCA 0
is LCA 1
OPAC
(continued)