Nortel DMS-100 Series Maintenance Manual page 482

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-116 Card replacement procedures
NT6X52
LCM
(continued)
24
25
26
27
28
297-8211-550 Standard 05.01 August 1999
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Reload the LCM unit by typing
>LOADPM UNIT lcm_unit CC
and pressing the Enter key.
where
lcm_unit
is the LCM unit to be loaded (0 or 1)
If
load failed
load passed
Return the LCM unit to service by typing
>RTS UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the LCM busied in step 5 (0 or 1)
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 30.
Do
step 29
step 26
Do
step 27
step 29

Advertisement