7-12 Alarm clearing procedures
OPAC
critical
(continued)
24
25
26
27
297-8211-550 Standard 05.01 August 1999
To busy both LCM units of the OPAC, type
>BSY PM
and press the Enter key.
Go to step 25.
To test both LCM units of the OPAC, type
>TST PM
and press the Enter key.
If test
passes
fails, and a the system generates a card list
fails, and the system does not generate a card
list
The card list identifies the cards that have possible faults. Replace the cards
one at a time in order as directed by this procedure.
If you
replaced the last card on the list
did not replace the last card on the
list
To return the OPAC to service, type
>RTS PM
and press the Enter key.
If MAP prompt
indicates RTS is successful
indicates CBsy
indicates load failure
indicates all other results
Do
step 25
step 26
step 27
Do
step 28
step 27
Do
step 33
step 5
step 26
step 27