Nortel DMS-100 Series Maintenance Manual page 337

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing an RMM minor alarm
At the MAP terminal:
1
To silence the alarm, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
2
To identify the RMM that has faults, type
>DISP STATE ISTB RMM
and press the Enter key.
Example of a MAP terminal response:
ISTb
RMM: 2
3
To post the ISTb RMM identified in step 2, type
>POST RMM rmm_no
and press the Enter key.
where
rmm_no
is the number of the RMM that has faults
4
To perform an in-service test on the RMM that has faults, type
> TST
and press the Enter key.
If test
passes
fails because C-side links are not
available
fails and the system generates a
card list
fails and the system does not
generate a card list
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Alarm clearing procedures 7-101
minor
(continued)
Do
step 17
step 5
step 14
step 16
RMM