Replacing an NT6X73 in an HIE
At your Current Location
1
Proceed only if you have been directed to this card replacement procedure from
a step in a maintenance procedure, are using the procedure for verifying or
accepting cards, or have been directed to this procedure by your maintenance
support group.
2
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
3
If you were directed to this procedure from the Alarm Clearing Procedures , go
to step 7. Otherwise, continue with step 4.
At the MAP terminal
4
Access the peripheral module (PM) level and post the line concentrating
module (LCM) by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the site name of the OPAC (alphanumeric)
frame
is the frame number of the OPAC (0 to 99)
lcm
is the number of the LCM
5
Use the following table to determine which LCM unit is associated with the
faulty NT6X73.
LCM unit
0
1
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Card replacement procedures 8-149
LCC card
LCC 0
LCC 1
NT6X73
HIE
(continued)
HIE slot
17
18