8-98 Card replacement procedures
NT6X50
HIE
(continued)
Replacing an NT6X50 in an HIE
At your Current Location
1
2
3
At the MAP terminal:
4
5
6
297-8211-550 Standard 05.01 August 1999
Proceed only if you have been directed to this card replacement procedure from
a step in a maintenance procedure, are using the procedure for verifying or
accepting cards, or have been directed to this procedure by your maintenance
support group.
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
If you were directed to this procedure from the Alarm Clearing Procedures , go
to step 5. Otherwise, continue with step 4.
Access the peripheral module (PM) level and post the line concentrating
module (LCM) by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the site name of the OPAC (alphanumeric)
frame
is the frame number of the OPAC (0–99)
lcm
is the number of the LCM
Display central side (C-side) link information by typing
>TRNSL C
and pressing the Enter key.
Example of a MAP response:
Link 0: LTC 0
Link 1: LTC 0
From the display in step 5, determine the control side (C-side) PM (LTC, LGC,
or RCC) to which the OPAC is connected and post it by typing
>POST pm pm_no
and pressing the Enter key.
where
pm
is the name of the host PM (LTC, LGC, or RCC)
pm_no
is the number of the host PM (0 to 127)
Note: LTC is the acronym for line trunk controller; LGC is the acronym for line
group controller; and RCC is the acronym for remote cluster controller.
2; Cap MS; Status:
6; Cap MS; Status: SysB;MsgCond: OPN
OK;MsgCond: OPN