8-60 Card replacement procedures
NT3X09
RMM
(continued)
At the MAP terminal
8
9
10
11
12
297-8211-550 Standard 05.01 August 1999
Go to the PM level and post the RMM, if not already posted, and return the
RMM to service by typing
>PM;POST RMM rmm_no;RTS
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
If RTS
passed
failed
Go to the TTP level of the MAP display and post the RMM by typing
>TRKS;TTP;POST P RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
Return to service the circuits busied in step 4 by typing
>RTS ALL
and pressing the Enter key.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 14.
Do
step 9
step 13
Do
step 11
step 13