Nortel DMS-100 Series Maintenance Manual page 503

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X60 in an HIE
At your Current Location
1
CAUTION
Loss of service
This procedure includes directions to manually busy
one or more peripheral module (PM) units. Since
manually busying a PM unit can cause service
degradation, perform this procedure only if necessary
to restore out-of-service components. Otherwise,
carry out this procedure during periods of low traffic.
Proceed only if you have been directed to this card replacement procedure from
a step in a maintenance procedure, are using the procedure for verifying or
accepting cards, or have been directed to this procedure by your maintenance
support group.
2
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
3
If you were directed to this procedure from the Alarm Clearing Procedures , go
to step 9. Otherwise, continue with step 4.
At the MAP terminal
4
Post the line concentrating module (LCM) with the HIE shelf containing the card
to be replaced by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the site name of the OPAC (alphanumeric)
frame
is the frame number of the OPAC (00–511)
lcm
is the number of the LCM in the OPAC cabinet
Example of a MAP response:
LCM REM1 00 0 ISTb Links
Unit 0: ISTb
Unit 1: InSv
Drwr:
01
23
45
..
..
..
DMS-100 Family OPAC Maintenance Manual XPM12 and up
OOS: Cside 0 Pside 0
/RG:1
/RG:1
11
11
11
67
89
01
23
45
..
..
..
..
..
Card replacement procedures 8-137
HIE
11
11
RG: Pref 0 ISTb
67
89
Stby 1 InSv
..
..
NT6X60
(continued)

Advertisement

Table of Contents
loading

Table of Contents