Nortel DMS-100 Series Maintenance Manual page 530

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-164 Card replacement procedures
NT6X75
HIE
(continued)
19
20
21
22
23
24
25
26
27
28
297-8211-550 Standard 05.01 August 1999
List the contents of the tape in your user directory by typing
>LIST T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape containing the PM load files
Demount the tape drive by typing
>DEMOUNT T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files.
Go to step 31.
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP terminal by typing
>DSKUT
and pressing the Enter key.
List the IOC file names into your user directory by typing
LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name is the name of the volume that contains the PM load files
identified in step 22.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 31.
From office records, determine and note the number of the system load module
(SLM) disk and the name of the volume that contains the PM load files.
Access the disk utility level of the MAP terminal by typing
>DISKUT
and pressing the Enter key.