7-40
7-40
Alarm clearing procedures
RLCM
major
Alarm display
CM
.
Indication
The alarm code RLCM under the peripheral module (PM) subsystem header
indicates a line concentrating module (LCM) alarm. The M under the LCM
indicates a major alarm. The number (n) before RLCM indicates the
number of OPACs with a major alarm.
Meaning
The number (n) indicates the OPACs that are in the manual busy (ManB),
system busy (SysB), or C-side busy (CBsy) state.
Result
The ManB and SysB units do not directly affect service. One unit of the
OPAC continues to provide service.
There is no local backup. A failure of the other unit of the OPAC will
interrupt service.
A CBsy condition can interrupt communication between the OPAC and the
host. This interruption reduces the service that the OPAC provides to the
local area.
Common procedures
There are no common procedures.
Action
This procedure contains a summary flowchart and a list of steps. Use the
flowchart to review the procedure. Use the steps to perform the procedure.
297-8211-550 Standard 05.01 August 1999